CEMEX Dilution-Extraction Continuous Emissions Monitoring System (CEMS)

Stack Gas Emissions Monitoring

Applications: Coal Fired Plants, Waste Fired Plants, Oil Fired Plants

Gases: SO2, NOx, CO, CO2

 

/files/Single System Cutout with door thumb.jpg

/files/Dilution Probe web.jpg

Single Cabinet (NEMA 12) CO2, NOx Dilution CEMS

Out-of-Stack Dilution Probe Internal Assembly

Monitoring Solutions CEMEX dilution system is the solution for a stack gas monitoring system that provides maximum data capture with minimum maintenance.

Dilution technology delivers a clean, dry, non-corrosive sample for analysis. The sample gas in the probe tip is diluted 20 to 750 times with clean, conditioned air, resulting in a system with no need for heat traced sample lines or dryers.

The Monitoring Solutions dilution probe is just one key component of an entire dilution system designed for high accuracy, reliability, and minimum maintenance.

The total system includes automatic daily calibration checks, automatic and manual purging of the probe, a dilution air clean-up system, and high accuracy analyzers. The entire package is tied together with Monitoring Solutions CEMDAS data acquisition and handling system to provide reports that are guaranteed to meet state and federal requirements.

Features:

Specifications

Parameter

Specification

Flue Gas Temperature Up to 1800 F
Probe Length Standard: 2-10 ft. Opt: Greater than 10 ft.
Rack/Shelter Utilities-Electrical 208-230 VAC, 60 Hz, 15A
Rack/Shelter Utilities - Instrument Air 10-20 SCFM - probe dry instrument air
Probe Utilities None
Data Interface - Analog Outputs 4-20 mA or 0-10 Vdc for each gas measured
Data Interface - Digital Outputs Normal/Service Status, zero & span cal indicators
Calibration Error Less than 5% of reading
Response Time Less than 5 minutes
Drifts (2 & 24 hours for zero & span) Less than 2% of full scale
Relative Accuracy Less than 10%
Weights & Sizes
Probe Body 30 lbs. total (Dependant on length)
Sample Line 1-2lbs./ft.
Probe Materials Inconel 600, Pyrex glass, 316L Stainless Steel